• head_banner

3.0mm 1Fiber TPU FTTX Drop cable G657A2 Fiber/G657B3 Fiber

Short Description:

Tight Buffer 900um 1-2Core
The tight buffer fiber wrapped with a layer of aramid yarn as strength member ,then completed with a layer of TPU/LSZH outer sheath


Product Detail

Product Tags

Video

Structure

Application

Used in pigtails and patch cords as interconnect lines of equipment
indoor horizontal distribution cable Riser

Features

- Small diameter, light weight and friendly;
- High tensile strength of aramid yarn meet the requirements of self-supporting andreduce the installation cost;
- Good mechanical and temperature performance;

Technical data sheet

Fiber Type

G657A2 Fiber G657B3 Fiber

Fiber

1Core

2Core

Outer diameter

mm

3.0

3.0mm

Weight

Kg/km

8.6

8.9

Tight buffer

Diameter

900um

Coating material

LSZH White

Mini load  Tension

N

Short term:1000  Long term:300

Mini Crush load

N/100mm

Short term:3000

Min Bend radius

Times diameter

30

Min Bend radius

Times diameter

15

Outer sheath

Material

TPU/LSZH  Black

Operation temperature range

-20 to + 60

Installation temperature range

-20 to + 60

Transport and storage temperature range

-20  to + 70

Optical Characteristics SINGLE MODE G657A2

Mode Field Diameter @ 1310 nm

9.2 ± 0.4 um

Mode Field Diameter @ 1550 nm

9.8-10.8 um

Cladding diameter

125.0 ±± 0.7mm

Core/cladding concentricity error

0.5um

Cladding non-circularity

0.7 %

Refractive index profile

Step

Design

Matched cladding

Primary coating material

UV curable acrylate

Primary coating Diameter

235-245 um

Optical Characteristics

Attenuation

@ 1310nm

£ 0.36 dB/km (cabling)

@ 1383nm

£ 0.34 dB/km

@ 1550nm

£ 0.22dB/km  (cabling)

Dispersion

@ 1288 ~ 1339nm

£ 3.5 ps/nm×km

@ 1550nm

£ 18 ps/nm×km

Zero dispersion wavelength

1300 – 1324 nm

Dispersion slope at zero dispersion wavelength

£ 0.092 ps/nm2×km

Cabled cut-off wavelength (lcc)

£ 1260 nm

Polarization mode dispersion link value

£ 0.2 ps/√km

Mechanical Characteristics

Proof stress level

≥0.69 GPa

Effective group index of refraction Neff

1.466(at 1310nm)

Effective group index of refraction Neff

1.467 (at 1550nm)

10turns radius 15mm                      1550nm

0.03dB

10turns radius 15mm                      1625nm

0.1dB

1turns radius 10mm                       1550nm

0.1dB

1turns radius 10mm                       1625nm

0.2dB

1turns radius 7.5mm                     1550nm

0.5dB

1turns radius 7.5mm                     1625nm

1.0dB

Main mechanical Factory Routine Test

Parameter

Test method

Test conditions

Acceptance criteria*

Tensile  strength

IEC 60794-1-21-E1

As per cable maximum tensile strength (max. Working tension) in table above

After 30 minutes  the maximum strain on the fibre should not exceed 0.2% and no attenuation change throughout test

Crush

IEC 60794-1-21-E3

Short time: 10 min Long time: 120 min

Load: As per maximum crush resistance in table above

Number of positions: 3 adjacent sections (ensuring one over tube and one over lay reversal

No damage  to the sheath or to the core structure and no attenuation change throughout test

Impact

IEC 60794-1-21-E4

Weight: 1.5 kg

Height: 1.0 m

Anvil radius: 12.5 mm Impacts: 1

After 5 minutes  no fibre breaks, no damage  to the sheath or to the core structure and no attenuation change throughout test

Torsion

IEC 60794-1-21-E7

Sample length: 1 m

Rotation: a) 180º clockwise, b) return to starting position, c) 180º anticlockwise, d) return to starting position. Four movements constitute one cycle).

Complete 10 cycles (a to d) in one minute maximum

During  the final tenth cycle at a), c) and after completion (no rotation) check transmitting  fibres. No fibre breaks, no damage  to the sheath or to the

core structure and no attenuation change throughout test

Bend

Bend under tension

IEC 60794-1-21- E11

Concurrent to

tensile test IEC 60794-1-21-E18A

Mandrel diameter: 30 x Cable OD Bend: 360º (1turn)

Mandrel diameter: 40 x Cable OD Bend: 360º (1turn)

No attenuation change throughout test

After 1minutenofibre breaks, no damage to thes heath or to the core structure and no attenuation change throughout test

 

Temperature cycling

IEC 60794-1-22-F1

Sample length: 1000 m (minimum)

Temperature range: – 10 °C to +70 °C

 

Packing

Fumigated stronger wooden coil or iron wooden coil  idea for long distance delivery .and idea size for the optimized the container loading

Delivery length :1-2KM