• head_banner

FTTH Drop Cable 2 core 3 Sealings 3 Steel Wire Outdoor Drop Cable

Short Description:

FTTH DROP CABLE 2CORE 3SEALINGS 3STEEL WIRE OUTDOOR DROP CABLE refers to a type of fiber optic cable used in Fiber-to-the-Home (FTTH) installations. It is designed for outdoor use and is commonly used to connect the optical fiber distribution network to individual homes or buildings.

This specific cable configuration has 1 fiber core, which carries the optical signal, and is protected by 3 sealings, providing additional layers of protection against moisture and other environmental factors. The cable also features 3 steel wires, which provide strength and durability to withstand outdoor conditions and prevent damage to the optical fiber.

Overall, the FTTH DROP CABLE 1CORE 3SEALINGS 3STEEL WIRE OUTDOOR DROP CABLE is designed to provide reliable and high-quality fiber optic connectivity to homes and buildings, ensuring efficient data transmission and communication.


Product Detail

Product Tags

Video

structure

Strength member (CSM): TWO STEEL WIRE 0.45mm

Messenger wire :  Solid  steel  wire  as  support , anti-corrosion Galvanized steel wire material with good protection

Fiber :New Grade   A  quality  color coated  fiber, G657A 1 Fiber with excellent bend radius performance  is  priority

Sheath: Low  smoke  zero  halogen  LSZH  LSOH   allows for safety and environmental protection.

application

The FTTH DROP CABLE 1CORE 3SEALINGS 3STEEL WIRE OUTDOOR DROP CABLE is used for outdoor Fiber-to-the-Home (FTTH) connections. It provides reliable and high-speed internet connectivity to individual homes or buildings.

Technical data sheet

Part code

FTTH-JH-1F

Number of Fibers

Unit

2

Strength member

Material

STEEL WIRE 0.45mm*2

Messenger wire

Material

Solid  wire   1.0mm

Outer sheath

Material

LSZH Black

Cable nominal  Diameter

MM ±0.1

2.0*5.2±0.2mm

Cable nominal weight

Kg/Km ±2

21

Max. working tension

N

600

Span

Meter

50/60

Max. crush resistance

N

600 (Short term) / 400(Long term)

Min. bending radius

At full load 20 x Cable OD (including  poles)

At no load 15 x Cable OD

Temperature range

Installation -0 -> +50  Operation -20 -> +70

SINGLE MODE G657A1

Mode Field Diameter @ 1310 nm

9.2 ± 0.4 um

Mode Field Diameter @ 1550 nm

9.8-10.8 um

Cladding diameter

125.0 ±± 0.7mm

Core/cladding concentricity error

0.5um

Cladding non-circularity

0.7 %

Refractive index profile

Step

Design

Matched cladding

Primary coating material

UV curable acrylate

Primary coating Diameter

235-245 um

Optical Characteristics

Attenuation

@ 1310nm

£ 0.36 dB/km (cabling)

@ 1383nm

£ 0.34 dB/km

@ 1550nm

£ 0.22dB/km  (cabling)

Dispersion

@ 1288 ~ 1339nm

£ 3.5 ps/nm×km

@ 1550nm

£ 18 ps/nm×km

Zero dispersion wavelength

1300 – 1324 nm

Dispersion slope at zero dispersion wavelength

£ 0.092 ps/nm2×km

Cabled cut-off wavelength (lcc)

£ 1260 nm

Polarization mode dispersion link value

£ 0.2 ps/√km

Mechanical Characteristics

Proof stress level

≥0.69 GPa

Effective group index of refraction Neff

1.466(at 1310nm)

Effective group index of refraction Neff

1.467 (at 1550nm)

10turns radius 15mm                      1550nm

0.03dB

10turns radius 15mm                      1625nm

0.1dB

1turns radius 10mm                       1550nm

0.1dB

1turns radius 10mm                       1625nm

0.2dB

1turns radius 7.5mm                     1550nm

0.5dB

1turns radius 7.5mm                     1625nm

1.0dB

Main mechanical Factory Routine Test

Parameter

Test method

Test conditions

Acceptance criteria*

Tensile  strength

IEC 60794-1-21-E1

As per cable maximum tensile strength (max. Working tension) in table above

After 30 minutes  the maximum strain on the fibre should not exceed 0.2% and no attenuation change throughout test

Crush

IEC 60794-1-21-E3

Short time: 10 min Long time: 120 min

Load: As per maximum crush resistance in table above

Number of positions: 3 adjacent sections (ensuring one over tube and one over lay reversal

No damage  to the sheath or to the core structure and no attenuation change throughout test

 

Impact

IEC 60794-1-21-E4

Weight: 1.5 kg

Height: 1.0 m

Anvil radius: 12.5 mm Impacts: 1

After 5 minutes  no fibre breaks, no damage  to the sheath or to the core structure and no attenuation change throughout test

Torsion

IEC 60794-1-21-E7

Sample length: 1 m

Rotation: a) 180º clockwise, b) return to starting position, c) 180º anticlockwise, d) return to starting position. Four movements constitute one cycle).

Complete 10 cycles (a to d) in one minute maximum

During  the final tenth cycle at a), c) and after completion (no rotation) check transmitting  fibres. No fibre breaks, no damage  to the sheath or to the

core structure and no attenuation change throughout test

Bend

Bend under tension

IEC 60794-1-21- E11

Concurrent to

tensile test IEC 60794-1-21-E18A

Mandrel diameter: 30 x Cable OD Bend: 360º (1turn)

Mandrel diameter: 40 x Cable OD Bend: 360º (1turn)

No attenuation change throughout test

After 1minutenofibre breaks, no damage to thes heath or to the core structure and no attenuation change throughout test

Temperature cycling

IEC 60794-1-22-F1

Sample length: 1000 m (minimum)

Temperature range: – 10 °C to +70 °C

 

Packing

Plastic axis and 4 stronger screw design fix tighten ,protection the flange loosen .with 5 layer Cardboard Carton and pallet suitable for container loading by sea .OEM Carton and drum are available. Delivery length :1-2km


仓储
装货图
展会

证书

检测1
检测2


  • Previous:
  • Next:

  • Write your message here and send it to us