Local area network/Subscriber network system/Fiber to the home(FTTH)/ Micro duct installation
1. Perfect cable structure with high fiber density
2. Accurate fiber length balance to ensure stable performance
3. No gel in cable core for water blocking
4. Sheath structure innovation to enhance blowing performance
5. Greater blowing distance
6. Fiber: G.G652D, G.657A1, G.657A2
Unless otherwise specified in this specification, all requirements shall be mainly in accordance with the following standard specifications.
Optical fiber:ITU-T G.652D、IEC 60794-2-50
Optical cable :IEC 60794-5、IEC60794-1-2
Fiber count(F) |
Nominal diameter(mm) |
Nominal weight(kg/km) |
Max tensile strength(N) |
Temperature(℃) |
12 |
5.2±0.1 |
25 |
500 |
-40 to +70 |
24 |
5.2±0.1 |
25 |
500 |
|
36 |
5.2±0.1 |
25 |
500 |
|
48 |
5.2±0.1 |
25 |
500 |
|
60 |
5.2±0.1 |
25 |
500 |
|
72 |
5.2±0.1 |
25 |
500 |
|
96 |
6.1±0.1 |
35 |
1000 |
|
144 |
7.9±0.1 |
57 |
1200 |
|
192 |
7.9±0.1 |
55 |
500 |
-20 to +70 |
216 |
7.9±0.1 |
55 |
500 |
|
288 |
9.4±0.1 |
78 |
1000 |
Fiber count(F) |
Blowing machine |
Suitable microduct(mm) |
Blowing distance in 10/8 duct(m) |
Blowing distance in 12/10 duct (m) |
Blowing distance in 14/12 duct (m) |
12 to 72 |
PLUMETTAZ PR-140 Minijet-400 15bar |
10/8 or 12/10 |
1800 |
2300 |
/ |
96 |
10/8 or 12/10 |
1800 |
2300 |
/ |
|
144 |
12/10 |
/ |
1200 |
/ |
|
192 to 216 |
12/10 |
/ |
1500 |
/ |
|
288 |
14/12 |
/ |
/ |
1500 |
Item |
Testing Method |
Testing Results |
||
Temperature cycling |
IEC 60794-1-2-F1 |
Allowable additional attenuation(1550nm) |
||
G.652B |
G.652D |
G.655 |
||
≤0.10 dB/km,reversible; |
||||
Water penetration |
Water column:1m、1m cable,Period:24 hours |
No water leak throught the open end of cable |
||
Filling compound flow |
70℃ Period:24 hours |
No compound flow from the cable |
Outdoor optical cable, indoor optical cable, indoor armored optical cable, air-blown optical cable, OPGW, optical jumper, etc.