Strength member (CSM) : GFRP
Tube: Thermoplastic material, containing up to 12 optical fibres fil ed with a low viscosity, thixotropic, non-melting gel ful y compatible with fibre coating and tube material .SZ Strands multi tube design
Additional armored :Fiberglass yarn di electric armored
Water block :water swellable tape and water block yarn
Sheath: polyethylene in
Heavy duty duct pipeline installation / Networking communication in transformer substation/As approach cable for OPGW project to transformer substation / More Lighten aera
Insulation full dielectric,SZ strands multi loose tube design With fiberglass yarn anti rodent like mouse ,Ant termite
Part code |
JH-GYFTY XXXF |
||||
Number of Fibers |
Unit |
8/12/24/36/48 |
72 |
96 |
144 |
Number of fiber in tube |
Nos |
8/6/6/12/12 |
12 |
12 |
12 |
Number of loose tube |
Nos |
1/2/4/3/4 |
6 |
8 |
12 |
Number of dummy filler |
Nos |
4/3/1/2/1 |
0 |
0 |
0 |
Central strength member |
Material |
FRP |
FRP |
FRP |
FRP+ PE Coated |
Loose tube |
Material |
PBT |
|||
Additional stregnth |
Material |
Fiberglass yarn |
|||
Outer sheath |
Material |
PE |
PE |
PE |
PE |
Cable nominal Diameter |
MM ±0.2 |
9.5 |
10.0 |
11 |
12.4 |
Cable nominal weight |
Kg/Km ±5 |
80 |
89 |
95 |
108 |
Max. working tension
|
N |
2100 |
2400 |
2600 |
3000 |
Max. crush resistance |
N |
2000 (Short term) / 1000 (Long term) |
|||
Min. bending radius |
At full load 20 x Cable OD (including poles) At no load 15 x Cable OD |
||||
Temperature range |
Installation -0 -> +50 Operation -10 -> +70
|
Mode Field Diameter @ 1310 nm |
8.7-9.5 mum |
||
|
|
|
|
Mode Field Diameter @ 1550 nm |
9.8-10.8mum |
||
Cladding diameter |
|
125.0 ±± 0.7mm |
|
|
|
|
|
Core/cladding concentricity error |
|
0.6 um |
|
Cladding non-circularity |
|
1.0 % |
|
Refractive index profile |
|
Step |
|
Design |
|
Matched cladding |
|
Primary coating material |
|
UV curable acrylate |
|
Primary coating Diameter |
|
235-250um |
|
Optical Characteristics |
|
|
|
Attenuation |
|
@ 1310nm |
0.36 dB/km (cabling) |
|
@ 1383±3nm |
0.34 dB/km |
|
|
|
@ 1550nm |
0.22dB/km (cabling) |
Dispersion |
|
@ 1288 ~ 1339nm |
3.5 ps/nm×km |
|
@ 1550nm |
18 ps/nm×km |
|
|
|
||
Zero dispersion wavelength |
|
1300 – 1324 nm |
|
Dispersion slope at zero dispersion wavelength |
0.092 ps/nm2×km |
||
Cabled cut-off wavelength (lcc) |
|
1260 nm |
|
Polarization mode dispersion link value |
0.2 ps/√km |
||
Mechanical Characteristics |
|
|
|
Proof stress level |
|
≥0.69 GPa |
|
The loss increase of 100 turns of fiber loosely wound with |
0.05dB (at 1550nm) |
||
25mm radius |
|
|
|
Effective group index of refraction Neff |
1.466(at 1310nm) |
||
Effective group index of refraction Neff |
1.467 (at 1550nm) |
plywood Delivery length 3km/Roll
Outdoor optical cable, indoor optical cable, indoor armored optical cable, air-blown optical cable, OPGW, optical jumper, etc.