Application: Self supporting Aerial
1. High performance optical network operating.
2. High speed optical routes in buildings (FTTX).
3. All types of fiber cables with different structures.
Standards:
Comply with stand YD/T 901-2009 as well as IEC 60794-1
Self supporting Aerial
1. High performance optical network operating.
2. High speed optical routes in buildings (FTTX).
3. All types of fiber cables with different structures.
Operating :-40℃ to +70℃
Storage :-40℃ to +70℃
1. Excellent mechanical and temperature performance
2. Critical protection to fibers.
Tube:Unit tube single mode
Water block:Gelly filling compound in tube and water block yarn and water swellable tape triple protection
Reinforcing: High modulus Steel Armored tape
Sheath: UV stabilised polyethylene in
Messenger wire :High strength 7strands Galvanized steel wire
Part code | JH-Fig8 GYXTC8S XXXF | ||
Number of Fibers | Unit | 4-12 | |
Loose tube | Material | PBT | |
Armored | Material | Corrugated steel tape | |
Water block | Material | Gelly filling compound | |
Messenger wire | Size and material | 0.9*7mm Galvanized steel wire | |
Outer sheath | Material | PE | PE |
Cable nominal Diameter | MM ±0.2 | 7x13.5 | |
Cable nominal weight | Kg/Km ±5 | 105 | |
Max. working tension |
N | 1800 | |
Max. crush resistance | N | 2200 (Short term) / 1100 (Long term) | |
Min. bending radius | At full load 20 x Cable OD (including poles)
At no load 15 x Cable OD |
||
Temperature range | Installation -0 -> +50 Operation -10 -> +70 |
Mode Field Diameter @ 1310 nm | 8.7-9.5 mum | ||
Mode Field Diameter @ 1550 nm | 9.8-10.8mum | ||
Cladding diameter | 125.0 ±± 0.7mm | ||
Core/cladding concentricity error | 0.6 um | ||
Cladding non-circularity | 1.0 % | ||
Refractive index profile | Step | ||
Design | Matched cladding | ||
Primary coating material | UV curable acrylate | ||
Primary coating Diameter | 235-250um | ||
Optical Characteristics | |||
Attenuation | @ 1310nm | £ 0.36 dB/km (cabling) | |
@ 1383±3nm | £ 0.34 dB/km | ||
@ 1550nm | £ 0.22dB/km (cabling) | ||
Dispersion | @ 1288 ~ 1339nm | £ 3.5 ps/nm×km | |
@ 1550nm | £ 18 ps/nm×km | ||
Zero dispersion wavelength | 1300 – 1324 nm | ||
Dispersion slope at zero dispersion wavelength | £ 0.092 ps/nm2×km | ||
Cabled cut-off wavelength (lcc) | £ 1260 nm | ||
Polarization mode dispersion link value | £ 0.2 ps/√km | ||
Mechanical Characteristics | |||
Proof stress level | ≥0.69 GPa | ||
The loss increase of 100 turns of fiber loosely wound with | £0.05dB (at 1550nm) | ||
25mm radius | |||
Effective group index of refraction Neff | 1.466(at 1310nm) | ||
Effective group index of refraction Neff | 1.467 (at 1550nm) |
The fibers shall be marked by a coloured coating with 12 different colours according to EIA/TIA 598:
Fibre #1: Blue Fibre #7: Red
Fibre #2: Orange Fibre #8: Black (natural with being marked
Fibre #3: Green Fibre #9: Yellow
Fibre #4: Brown Fibre #10: Violet
Fibre #5: Grey Fibre #11: Pink
Fibre #6: White Fibre #12: Aqua (Light Blue)
No. | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
Colour | blue | orange | green | brown | grey | white | red | black | yellow | violet | pink | aqua |
Sheath Colour:
The outer sheath colour is black or white
Sheath Marking:
The outer sheath is marked white color in 1 metre intervals as follows:
JIAHOME or your brand FIG GYXTC8S PART NUMBER OR YOUR ORDER NUMBER year of
Note:The sheath with color strip are available ,should be inform before production
Fumigated stronger wooden coil or iron wooden coil idea for long distance delivery .and idea size for the optimized the container loading
Delivery length :2-6km
Parameter | Test method | Test conditions | Acceptance criteria* |
Tensile strength | IEC 60794-1-21-E1 | As per cable maximum tensile strength (max. Working tension) in table above |
After 30 minutes the maximum strain on the fibre should not exceed 0.2% and no attenuation change throughout test |
Crush | IEC 60794-1-21-E3 |
Short time: 10 min Long time: 120 min Load: As per maximum crush resistance in table above Number of positions: 3 adjacent sections (ensuring one over tube and one over lay reversal |
No damage to the sheath or to the core structure and no attenuation change throughout test |
Impact | IEC 60794-1-21-E4 | Weight: 1.5 kgHeight: 1.0 m
Anvil radius: 12.5 mm Impacts: 1 |
After 5 minutes no fibre breaks, no damage to the sheath or to the core structure and no attenuation change throughout test |
Torsion | IEC 60794-1-21-E7 | Sample length: 1 mRotation: a) 180º clockwise, b) return to starting position, c) 180º anticlockwise, d) return to starting position. Four movements constitute one cycle).
Complete 10 cycles (a to d) in one minute maximum |
During the final tenth cycle at a), c) and after completion (no rotation) check transmitting fibres. No fibre breaks, no damage to the sheath or to thecore structure and no attenuation change throughout test |
BendBend under tension | IEC 60794-1-21- E11Concurrent to
tensile test IEC 60794-1-21-E18A |
Mandrel diameter: 30 x Cable OD Bend: 360º (1turn)Mandrel diameter: 40 x Cable OD Bend: 360º (1turn)
|
No attenuation change throughout test
After 1minutenofibre breaks, no damage to thes heath or to the core structure and no attenuation change throughout test |
Temperature cycling | IEC 60794-1-22-F1 | Sample length: 1000 m (minimum)Temperature range: – 10 °C to +70 °C |
All optical measurements for single mode fibers performed at 1550 nm
Outdoor optical cable, indoor optical cable, indoor armored optical cable, air-blown optical cable, OPGW, optical jumper, etc.